Specifications for 3500 mobile PCA

For the ITW GSE 3500 Mobile PCA 150 & 210

Input

  • Rectification: 12 pulse
  • Line current distortion: < 10%
  • Inrush current: None, softstart
  • Power factor: >0.97 at 100% load

Output

  • Discharge air temperature: Down to 0°C / 32°F, depending on ambient temperature, relative humidity, and air flow. For specified cooling calculations, please contact your Regional Sales Office.

Environmental data

  • Operating temperature:
    -30°C to +50°C (-22°F to +122°F)
  • Relative humidity: 10-100%, non condensing
  • Noise level: < 85 dB(A) at 4.6 m
  • IP class: IP54 (Electronic part)

Miscellaneous

  • MTTR: Typically 20 minutes
  • Available refrigerants: R410A & R454B
  • Construction: Welded and bolted galvanized steel frame
  • Max speed: 15 km/h

Directive conformity

  • 2004/108/EC EMC Directive
  • 2006/95/EC LVD Directive
  • 2006/42/EC Machinery Directive

Norms and standards

  • EN61000-6-2    EMC - immunity standard
  • EN61000-6-4    EMC - emission standard
  • EN62040-1-1     LVD safety standard
  • EN1915-1&2       Machinery - general safety requirement
  • EN12312-17       Aircraft ground support equipment, specific requirements

Available options

  • ePM1 70% fine filtration (EN779: F8 / ASHRAE 52.2: MERV 14 eq.)
  • Removable heater module with overtemperature protection
  • Condensate separator for hot and humid climates
  • Cover for modules (RAL 7035)
  • 14'' single outlet (for PCA 210 only)
  • Single or dual dolly-mounted Air Coil

Standard features

  • Stepless regulation via VFD on main blower, compressors and heater
  • Quick swap of cooling module
  • Internal ducts made of stainless steel
  • Smoke detector
  • Measure of outlet pressure and air flow
  • Air temperature sensors (discharge and inlet)
  • 2 pressure and 3 temperature sensors as well as 1 sight glass on each refrigerant circuit
  • Micro channel condensers (sea water resistant aluminium)
  • ePM10 70% medium filtration including clogging alarm (EN779: M6 / ASHRAE 52.2: MERV 11 eq.)
  • Internal 14'' damper on the second outlet
  • Special condenser coating
  • Fast evaporator de-icing
  • Color: RAL 7035 (standard) or any other RAL colour on request
  • Refrigerant leak detector (only in units with R454B)
  • Remote control box with display and single communication cable